Single Channel Temperature Data Logger
ACR JR. Data Logger
Type: Negative Temperature Coefficient Thermistor (NTC). 10,000 ohms @ 25° (77°F)
Range: -40°C to 85°C. (-40°F to 185°F).
Resolution: 0.4°C @ 25°C. (0.7°F @ 77°F).
Sensor Accuracy: +/-0.2°C. (+/-0.3°F).
Memory Size: 8 K (up to 44 days).
Software: See Software

JR-1000

JR-1001

 

JR-1001

The JR-1000 is a low-cost, user configurable temperature logger that plugs easily into any computer for data download. Featuring a 5-year battery life, it has the capacity to record for up to 44 days.

Specifications

Logger Resolution 0.4°C @ 25°C (0.7°F @ 77°F)
Memory Size 32 KB (up to 244,800 readings when data compression selected)
Temperature Sensor Type NTC Thermistor 10,000 ohms @ 25°C (77°F)
Temperature Sensor Range: -40 to 85°C (-40 to 185°F)
Temperature Sensor Accuracy +/- 0.2°C @ 25°C (+/- 0.3°F @ 77°F)

Ordering Information

Model Description Catalog #
JR-1000 Single channel temperature data logger 01-0192

$190.00 

 JR-1002

The JR-1001 data logger is an Intrinsically Safe, simple and easy-to-use single- channel data logger. It is ideal for quick and accurate temperature recordings in a variety of applications.

Specifications

Sampling Interval User selectable from 8 seconds to 34 minutes
Sampling Method Continuous, Stop when Full
Logger Resolution 0.4°C @ 25°C (0.7°F @ 77°F)
Memory Size 32 KB (up to 244,800 readings when data compression selected)
Temperature Sensor Type NTC Thermistor 10,000 ohms @ 25°C (77°F)
Temperature Sensor Range: -40 to 85°C (-40 to 185°F)
Temperature Sensor Accuracy +/- 0.2°C @ 25°C (+/- 0.3°F @ 77°F)
Approval UL Intrinsically Safe for use in:
Class 1, Division 1, Groups A, B, C, D
Class 2, Division 1, Groups E, F, G
Class 3, Division 1, Hazardous Locations T3C
... ...

Ordering Information

Model Description Catalog #
JR-1001 Single channel temperature data logger 01-0193

 

$355.00  

Size: 33 x 43 x 15 mm (1.3 x 1.7 x 0.6").
Weight: 1 ounce (29 grams).
Case Material: Polyurethane.
Operating Limits: -40°C to 85°C (-40°F to 185°F). 0 to 95% RH (non-condensing).
Clock Accuracy: +/-2 seconds per day.
Battery: 3 volt Lithium; 0.5 Amp-Hour.
Battery Life: Five years warrantied (under normal use).
Mounting: Magnetic backing.
Memory Size: 8 K (with compression up to 32 K). Typical 22 days (depending on the rate of temperature change). Maximum 44 days.
Sampling Method: First-in First-out.
Sampling Rate: One reading every 2 minutes.
Resolution: 8 bit (1 part in 256).
PC Requirements: IBM PC or 100% compatible running MS Windows 3.1, 95, 98, or NT, with a least 2 MB RAM, 2 MB of hard drive disk space and one free serial port.
Software Requirements: TrendReader® Express (compatible with Windows® 3.1, 95, 98, 2000, Me, NT, 2000 and XP).
Product Approvals: Meets Part 15 for Digital Devices of the Code of Federal Regulations of the Federal Communications Commission (FCC). Meets Class A radiated and conducted emission requirements of Section 2 of the Radio Interference Regulations of Communications Canada. IEC801-2, 3, 4 and EN55011 covering ESD, RFI Immunity, EFT/Burst and Radiated Emissions respectively for the Commission of the European Communities (CE).
Resistance to X-Rays: Tested for protection against a 160kV dose @ 5mA for 30 seconds (150mA-sec) @ 38 inches F.F.D. (about 100 times that of an airport X-Ray machine). Tested for protection against Gamma Ray (equivalent to 0.137 - 1.38 mega volts) IR 192 - 28 curies @ 30 second exposure source to object distance 5".

Select the product you require by clicking on the    button.  If you need specific assistance please email or call our toll free number.  We can be reached at (800) 576-6308.  Our fax number is (714) 751-0213.  


Main Page

 OWL

ACR jr

SmartReader

SmartReader+

 PowerWatch

Accessories

Software

Networking

Home