Single Channel Temperature Data Logger
OWL MODEL 100
Memory Size: 32 KB
No. of Channels: One. (Ambient temperature).
Thermistor Type: NTC Thermistor (10K ohms @ 25° C).
Total Accuracy: +/-0.5° C @ 25° C (0.9° F @ 77° F). Can be increased by using narrow range feature.
Standard Resolution: 0.5° C (0.9° F) at 25° C (77° F). Better than 1° C (1.8° F) between -25° C (77° F) and 70° C (158° F). Better than 2.0° C (3.6° F) between-40° C (-40° F) and -25° C (-13° F). Can be increased by using narrow range feature.
Submergence Rating: 100 m (328') in fresh water (OWL-100-Poly only). OWL-100-Plastic not submersible.
DataSheet Click for .pdf
Software: See Software

 

$350.00

 

 
Single Channel Temperature Data Logger   
OWL MODEL 200 
Memory Size: 32 KB.
Accessories: ACR OWL ET Series Temperature Probe.
Any NTC Thermistor Probe.
No. of Channels: One. (External temperature, resistance or switch status).
Logger Accuracy: +/-1% of range.
DataSheet Click for .pdf
Software: See Software

$350.00

.(800) 576-6308 for Application Assistance                           

Single Channel AC Current Data Logger   
OWL MODEL 300 
Frequency Range: 60 Hz - A60FL and A70FL current probes.
50 Hz - A65FL and A75FL current probes.
Current Ranges: With OWL A60FL and A65FL:
current probes: 5, 25, 100, 250 Amps.
With OWL A70FL and A75FL:
current probes: 10, 50, 250, and 500 Amps.
Accuracy: +/-4% F.S. above 10% of range.
Memory Size: 32 KB.
Accessories: OWL AC Current Probes.
DataSheet Click for .pdf
Software: See Software

$350.00

.(800) 576-6308 for Application Assistance                             

Single Channel DC Voltage Data Logger  
OWL MODEL 400 
Input Range: 0 to 38.4 volts max. DC (software selectable ranges available).
Accuracy: +/-1% of full scale.
Memory Size: 32 KB.
No. of Channels: One. (External DC voltage).
Input Impedance: Greater than 100 K ohms.
DataSheet Click for .pdf
Software: See Software

$350.00

.(800) 576-6308 for Application Assistance                            

Single Channel DC Current Data Logger  
OWL MODEL 500
Input Range: 0 to 24 mA max. DC.
Accuracy: +/-1% of full scale.  
Memory Size: 32 KB.
No. of Channels: One. (External DC Current).
Input Impedance: 100 ohms
DataSheet Click for .pdf
Software: See Software

$350.00

 

Single-channel, configurable, data loggers  - Common Specifications - All Models 

Size: 60 mm x 48 mm x 19 mm (2.4" x 1.9" x 0.7").
Weight: Watertight model (OWL 100); 80 g (2.8 oz.). Non-watertight model; 54 g (1.9 oz.).
Case Material: Watertight model (OWL 100 only);Polyurethane. Non-watertight model; Noryl® Plastic.
Operating Limits: -40°C to 70°C (-40°F to 158°F); 0 to 95% RH (non-condensing) on non-watertight models.
Clock Accuracy: +/ - 2 seconds per day.
Battery: 3.6 volt Lithium, 10-years Warrantied (under normal use). Factory replaceable.
Memory Size: 32 K (32,767 readings).
Sampling Method: First-in, First-out, (First-in, First-out not available with sample rates faster than 8 seconds). Fill-then-stop, Delayed start, Trigger start.
Sampling Rate: User selectable rates from 5 per second to once every 12 hours.
Resolution: 8 bit (1 part in 256). Can be optimized to the equivalent of 10 bit resolution.
Communication: Optical Send/Receive from up to 1" between logger and interface cable (with no obstructions).
Alarm Type: Optical (Red LED).
External Connector: Removable snap type connector.
PC Requirements: IBM PC or 100% compatible running MS Windows 3.1,95,98, or NT, with a least 2 MB RAM, 2 MB of hard drive disk space and one free serial port.
Product Approvals: Meets Part 15 for Digital Devices of the Code of Federal Regulations of the Federal Communications Commission (FCC). Meets Class A radiated and conducted emission requirements of Section 2 of the Radio Interference Regulations of Communications Canada. IEC801-2, 3, 4 and EN55011 covering ESD, RFI Immunity, EFT/Burst and Radiated Emissions respectively for the Commission of the European Communities (CE).
Resistance to X-Rays: Tested for protection against a 160V dose @ 5mA for 30 seconds (150mA-sec) @ 38 inches F.F.D. (about 100 times of an airport X-Ray machine). Tested for protection against Gamma Ray (equivalent to 0.137-1.38 mega volts) IR 192 - 28 curies @ 30 second exposure source to object distance 5".