Two Channel Temperature Data Logger

SmartReader 1
Memory Size: 32 KB.
Accessories: ACR ET Series Temperature Probe.
No. of Channels: Two. (One for the internal temperature sensor and one for remote sensing of temperature, resistance, or switch status).
Remote Network Communications: See Network & Communications
Common Specifications: See Common Specs
Software: See Software
PDF: View PDF

 

$465.00

Four Channel RH and Temperature Data Logger

SmartReader 2
Range:   0 to 95% (non-condensing).
Resolution: Better than 0.4% between 25 & 60% RH at 25° C (77° F).
Accuracy: +/-4% RH from 10 to 90% (-20° to 40°C [-4 to 104°F]).
Memory Size: 32 KB.
Accessories: ACR EH-020A Temperature & RH Probe
ACR ET Series Temperature Probe.
No. of Channels: Four. (One for the internal temperature sensor, one for the internal RH sensor, one for optional external RH and one for optional external temperature or resistance).
Relative Humidity Sensor: Capacitive thin polymer film.
Response Time: Adequate ventilation reduces the response time which is approximately 5 minutes in still air.
Environmental Conditions: Like all relative humidity sensors, when exposed to contaminants and/or extreme environmental conditions, accuracy degradation could result. For maximum long-term stability, sensor should not be exposed or subjected to organic solvents, corrosive agents (strong acids, SO2, H2SO4, CI2, HCl, H2S, etc.), and strong bases (compounds with PH greater than 7). Dust settling on the sensor surface will not affect sensor performance except possibly to decrease the speed of response. For more information on the RH sensor’s tolerance to chemicals, see Accessories section under Relative Humidity.
Remote Network Communications: See Network & Communications
Common Specifications: See Common Specs
Software: See Software
PDF: View PDF

$860.00

(800) 576-6308 or email for Application Assistance

Four Channel AC Current Data Logger

SmartReader 3
Accessories: ACR AC Current Probes
Remote Network Communications: See Network & Communications
Common Specifications: See Common Specs
Software: See Software
PDF: View PDF

$680.00

(800) 576-6308 or email for Application Assistance

Five Channel Pressure, Temperature and RH Data Logger

SmartReader 4
Memory Size: 32 KB
Accessories: ACR Pressure Modules.
ACR RH-002 RH Sensor.
ACR EH-020A RH/Temp. Probe.
ACR ET Series Temp. Probes.
Any NTC Temp. Probe.
No. of Channels: Five. (One for ambient temperature, one for optional Pressure Module, one for optional on-board RH sensor, one for optional remote thermistor and one for optional remote Relative Humidity probe).
Remote Network Communications: See Network & Communications
Common Specifications: See Common Specs
Software: See Software
PDF: View PDF

$740.00

(800) 576-6308 or email for Application Assistance
Range Resolution Guage Absolute
P/N Cat. # P/N Cat. #
0 to 5 psi (30kPa) 0.03 psi (0.2kPa) PM-005-G #01-0045 N/A N/A
0 to 30 psi (200kPa) 0.15 psi (1.0kPa) PM-030-G #01-0047 PM-030-A #01-0046
0 to 100 psi (100kPa) 0.5 psi (3.5kPa) PM-100-G #01-0049 PM-100-A #01-0048
0 to 150 psi (1000kPa)  0.5 psi (3.5kPa) PM-150-G #01-0086 N/A N/A

Three Channel Temperature Data Logger

SmartReader 5
Accuracy: +/- 1% span + resolution.
Memory Size: 32 KB.
Accessories: Any J, K, S, T type Thermocouple.
No. of Channels: Three. (One internal thermistor for cold-junction compensation and two external; one for narrow range thermocouple applications, the other for a wider range).
Remote Network Communications: See Network & Communications
Common Specifications: See Common Specs
Software: See Software
PDF: View PDF

$479.00

Seven Channel Temperature Data Logger

SmartReader 6
Accuracy: +/-1% span + resolution
Memory Size: 32 KB
Accessories: Any J, K, S, T and E thermocouple
No. of Channels: Seven. (One internal thermistor for cold-junction compensation and six external thermocouple channels. Specify narrow or wide temperature range when ordering).
Remote Network Communications: See Network & Communications
Common Specifications: See Common Specs
Software: See Software
PDF: View PDF

$899.00

Thermocouple Temperature Range & Resolution for each Channel

Thermocouple Type Channel 1 (Narrow) Charnnel 2 (Wide)
Range Resolution Range Resolution
J -20 to 190ºC (0 to 370ºF) 1.4ºC (2.5ºF) -50 to 600ºC (-55 to 1100ºF) 5ºC (9ºF)
K -25 to 230ºC (-10 to 440ºF) 1.7ºC (3ºF) -100 to 900ºC (-145 to 1650ºF) 6.7ºC (12ºF)
S 0 to 960ºC (32 to 1750ºF) 7.0ºC(12.6ºF) 0 to 1760ºC (32 to 3200ºF) 23ºC (41.5ºF)
T -35 to 200ºC (-30 to 390ºF) 1.7ºC (3ºF) -200 to 400ºC (-325 to 750ºF) 6.7ºC (12ºF)

Eight Channel Process Signal Data Logger

SmartReader 7
Standard Input Ranges: 0 to 2.5 volts DC.
0 to 5.0 volts DC (two channels).
0 to 10.0 volts DC.
0 to 200 millivolts DC.
0 to 25 milliamps DC (two channels).
Optional Input Ranges: All external channels 0 to 2.5 volts, 0 to 5 volts, 0 to 10 volts, or 0 to 25mA
Accuracy: +/-1% full scale.
Memory Size: 32 KB.
No. of Channels: Eight. (One internal for ambient temperature and seven external for analog voltage and current loop signals).
Input Impedance: Greater than 1 M ohm (200 mV channel).
Greater than 1 M ohm (0 to 2.5 V channel).
20 K ohms (0 to 5.0 V channels).
40.9 K ohms (0 to 10.0 V channel).
100 ohms (0 to 25 mA channels).
Transducer Restrictions: The use of a single power supply is recommended to avoid ground loops or use loop isolators.
Maximum Protection
Voltage Channels: +/-40 volts (reverse-polarity protected).
Current channels: +/- 70 mA (reverse-polarity protected).
Remote Network Communications: See Network & Communications
Common Specifications: See Common Specs
Software: See Software
  View PDF

$920.00

Eight Channel Temperature Data Logger

SmartReader 8
Memory Size: 32 KB.
Accessories: ACR ET Series Temperature Probe.
Any NTC Thermistor Probe.
No. of Channels: Eight. (One internal for ambient temperature and seven external for either temperature, resistance, or switch status).
Remote Network Communications: See Network & Communications
Common Specifications: See Common Specs
Software: See Software
PDF: View PDF

$815.00

Three Channel Pulse Data Logger

SmartReader 9
Range: 32 Pulses/second; 64 Pulses/second;
128 Pulses/second
Memory Size: 32 KB.
No. of Channels: Three. (One internal thermistor and two external inputs for externally-generated pulse signals or dry switch contact closures)
Input Impedance: 750 K ohms.
Minimum Pulse Width: 4 milliseconds.
Switch Contact Closure Input (Input Type): Uncommitted switch or relay contacts.
Logic Inputs
Logic Type: Active logic signals.
Input Voltage: Low= 0 to 0.5 volts (DC). High= 4.5 to 24 volts (DC).
Remote Network Communications: See Network & Communications
Common Specifications: See Common Specs
Software: See Software
PDF: View PDF

$695.00

Single-channel, configurable, data loggers  - Common Specifications - ll Models 
Size: 107 X 74 X 22 mm (4.2 X 2.9 X 0.9").
Weight: 110 grams (3.75 ounces)
Case Material: Noryl® Plastic
Operating Limits: -40°C to 70°C (-40°F to 158°F) and 0 to 95% Relative Humidity (non-condensing).
Clock Accuracy: +/-2 seconds per day.
Battery: 3.6 volt Lithium, 1 Amp-Hour
Power Consumption: 5 to 10 microamps (continuous).
Battery Life: 10-years warrantied (under normal use.) Factory replaceable.
Mounting: Magnetic backing or locking eyelet.
Memory Size: 32 K (32,768 readings).
Sampling Method: 1. Continuous (First-in, First-out) 2. Stop when full (Fill-then-stop).
Sampling Rate: User selectable rates between 8 seconds to once every 5 days.
Resolution: 8 bits (1 part in 256).
External Connector: Removable screw-type terminal strip with Common (-) connection.
PC Requirements: IBM PC or 100% compatible running MS® Windows 3.1, '95, '98, or NT, with at least 2 MB RAM, 2 MB of hard drive disk space and one free serial port.
Product Approvals: Meets Part 15 for Digital Devices of the Code of Federal Regulations of the Federal Communications Commision (FCC). Meets Class A radiated and conducted emission requirements of Section 2 of the Radio Interference Regulations of Communications Canada. IEC801-2, 3, 4 and EN55011 covering ESD, RFI Immunity, EFT/Burst and Radiated Emissions respectively, for the Commission of the European Communities (CE).
Resistance to X-Rays: Tested for protection against a 160kV dose @ 5mA for 30 seconds (150mA-sec) @ 38 inches F.F.D. (about 100 times that of an airport X-Ray machine). Tested for protection against Gamma Ray (equivalent to 0.137 - 1.38 mega volts) IR 192 - 28 curies @ 30 second exposure source to object distance 5".

Internal Temperature Sensor
Type: Negative Temperature Coefficient Thermistor. 10,000 ohms @ 25°C (77°F).
Tolerance (sensor only): +/-0.2°C, over the range of 0 to 70°C (+/-0.3°F, over the range of 32 to 158°F).
Range: -40° to 70°C (-40° to 158°F).
Resolution: 0.4°C (0.7°F) @ 25°C. Better than 1°C (1.8°F) between -25°C (-13°F) and 70°C (158°F). Better than 2.0°C (3.6°F) between -40°C (-40°F) and 25°C (-13°F)