Up to 10 SmartReader Plus Data Loggers can
be networked to one modem or PC. To network the loggers,
run stereo or telephone cable around the site. Loggers can
be connected anywhere along the cable using an ACR YA-200
adapter (for stereo cable) or YA-201 adapter (for Telco
cable) installations. On one end of the cable, plug in an
ACR Power Supply and the opposite end, the IC-101
interface cable. To connect to a modem, use the MA-100
Modem Adapter between the modem and the IC-101, if
connecting the network directly to a PC, connect the
IC-101 directly to the PC's serial port.
YA-200 $25.00
YA-201 $24.00 |