Key Features |
| Economical
Liquid Flow Sensor |
| |
| Applications |
| Laser
Cooling Systems Heat Pumps Cooling Systems |
| |
| Features |
| |
Non-Adjustable
Flow Monitor |
| |
Low
Maintenance |
| |
Close
On-Off Differential |
| |
No
Seals |
|
Single
Moving Part |
|
In
Line Vertical Plumbing |
|
Materials:
316ss, Brass or PVC |
|
Confirms:
Normal Flow Condition |
|
Senses:
High flow or Low flow conditions |
|
Output:
Switch Contact |
|
| |
|
| |
| Operation |
As
flow is established upward through the unit and continues
to increase, the pressure differential across the
magnetic piston increases until it overcomes the magnetic
piston's resistance (mass). This force causes it to
progress fully upward to actuate the dry reed switch.
This is a snap action and occurs in the decreasing
mode as well.
|
| |
| |
Actuation
Points for increasing flow |
| |
Flow
Setting Accuracy ± 10% of actuation point |
| |
Deactuation
(decreasing flow) averages 10% less than actuation
(increasing flow) |
| |
Repeatability
± 2% |
|
Unit
will pass greater flows |
|
|
| |
|
| Calibration
Range in Water LPM (GPM) |
| |
FS-50 |
FS-75 |
FS-I |
| Calibration
Poit |
PVC |
Brass
or 316ss |
PVC |
Brass
or 316ss |
PVC |
Brass
or 316ss |
| A |
0.57
(0.15) |
0.95
(0.25) |
0.76
(0.20) |
1.89
(0.50) |
0.95
(0.25) |
7.57
(2.00) |
| B |
0.95
(0.25) |
1.89
(0.50) |
1.89
(0.50) |
3.79
(1.00) |
2.84
(0.75) |
9.46
(2.50) |
| C |
1.89
(0.50) |
3.79
(1.00) |
2.84
(0.75) |
7.57
(2.00) |
3.79
(1.00) |
11.4
(3.00) |
| D |
2.84
(0.75) |
5.68
(1.50) |
3.79
(1.00) |
11.4
(3.00) |
7.57
(2.00) |
15.1
(4.00) |
| E |
3.79
(1.00) |
7.57
(2.00) |
5.68
(1.50) |
15.1
(4.00) |
11.4
(3.00) |
22.7
(6.00) |
| F |
4.73
(1.25) |
9.46
(2.50) |
7.57
(2.00) |
21.8
(5.75) |
15.1
(4.00) |
32.2
(8.50) |
|
| Pressure
Loss Table |
| |
DP
To Atmosphere
at Set Point
PSID (BARD) |
Water
at Set Point
PVC Units
All Set Points |
0.034
(0.50) |
Metal
Units
All Set Points |
0.069
(1.00) |
|
| |
|
| Switch
Data |
SPST
Hermetically Sealed
Reed Switch |
SPDT
SPDT
is not recommended for A/C |
Max
Switching Voltage DC (V) 200 AC (V) 150 |
Max
Switching Voltage DC (V) 100 |
Contact
Rating DC (W) 50 AC (VA) 70 |
Contact
Rating DC (W) 3 |
Max.
Switching Current DC (A) 1.0 AC (A) 0.7 |
Max.
Switching Current DC (A) .25 |
|
| Leads |
SPST
Leads 18 in. min. from body 22 AWG, TFE insulation. |
 |
SPDT
(optional) Leads 18 in. min. from body 24 AWG,
TFE insulation.
- green
- N.C.
- blue
- N.O.
- white
- Common
|
|
|
Above
values for resistive loads only. For inductive loads,
surge current and rush current -- contact protection
is required; consult your local representative. SPDT
unit not UL Recognized. |
| |
| Specifications |
| Materials |
Maximum
Working Pressure
PSIG (BARG) |
Wetted
Parts |
| PVC |
100
(6.89) |
PVC,
Epoxy, Titanium |
| Brass |
250
(17.22) |
Brass,
Epoxy, Titanium |
| 316ss |
500
(34.45) |
316ss,
Epoxy, Titanium |
|
| |
| |
Inlet/Outlet
Ports (Inches) |
| Fluid
Ports |
FNPT
(PVC) |
MNPT
(Brass or 316ss) |
| FS-50 |
1/2" |
1/2" |
| FS-75 |
3/4" |
3/4" |
| FS-1 |
1" |
1" |
|
| |
Electrical
Conduit: 1/2"
FNPT (PVC Model only) |
Temperature
Operating Range: 32°
to 220° F (0° to 104° C) for Brass and Stainless Steel
32° to 120° F (0° to 49° C) for PVC. For other temperature
ranges, consult factory. |
Installation:
|
Metallic
Bodies Only: Mount
with inlet down vertically. Leads up - Normally Open;
Leads Down - Normally Closed. |
PVC:
N.O.
Conduit Offset Up; N.C. Conduit Offset Down. |
Filtration -