Bargraph
Panel Instruments for
Commercial and Nuclear Applications
AMETEK
Dixson's bargraphs are divided into two
groups:
All commercial and nuclear-rated bargraphs are
powered by 110 VAC. The numbers in each model number refer to
the number of segments in the instrument. For example, BB101P
bargraphs contain 101 segments; BB202P bargraphs contain 202
segments (101 segments in each of the two channels); the BW051P
contains 51 segments, and so on.
All
AMETEK Dixson bargraphs are fully warranted for two years.
Features
(NOTE: Not
all features are available in all combinations or models. Please
download our Bargraph Feature Matrix for exact configuration
availability)
- Tri-color LED bar display
- Brilliant red LED digital and bar displays
for excellent visibility
- Custom scaleplates - you specify, we make
- Minimum 88,000-hour MTBF
- On/off control using set point relays
- Standard and DIN sizes
- Green and
amber bar
LEDs available
- Front panel mounting on most models
- Underrange/overrange indication
- True minus-sign indication
- Programmable configuration using front
panel switches or PC serial link
- Input ranges switch-selectable
- Auto-calibration algorithm
- Input signal linearization
- Min/Max signal memory (peak/valley hold)
- All models available with or without front
programming
Commercial
Bargraphs
Commercial bargraphs are designed for use in non-nuclear
environments. They may be used as HI-LO, on/off, or
differential gap controllers and/or annunciators in process
or other control applications. Fully programmable, these are
the preferred choice for new applications, or for
replacement of set point controllers, switchboard meters,
other common size indicators.
Nuclear-Rated
Bargraphs
Class I (1E) and Class II (seismic only)
nuclear-rated bargraphs are functionally identical to their
commercially-rated counterparts but they include the
following:
-
Software for the Class I bargraphs has been verified
and validated (V&V) to IEEE-7.4.3.2, 1993 standards.
-
EMI/RFI testing has been performed to current Nuclear
Utility requirements
-
Mild-environment qualification to IEEE-323-1983 and
IEEE-344-1987
Dixson's Quality programs include 10CFR50, Appendix B,
audited by a member of NUPIC.
Use the following table to associate commercial bargraphs
with their Class I and Class II counterparts.
| Commercial |
Class I |
Class II |
| BB101/202P |
SA101/202P |
BA101/202P |
| BG101/202P |
SH101/202P |
BH101/202P |
| BJ101/202P |
SN101/202P |
BN101/202P |
| BL101/202P |
SL101/202P |
AL101/202P |
| BS101/202P |
SS101/202P |
AS101/202P |
| BT033P |
ST033P |
AT033P |
| |
|
|
Please call 970-244-1241 for additional information
and assistance with order placement.
Downloads:
Bargraph
Brochure
Bargraph
Feature Matrix
|