- Zirconium oxide O2 sensor housed in 700°C furnace for exceptional accuracy and reliability
- Ex-situ convection loop design for simple installation and fast, easy maintenance
- Suitable for temperatures to 1900°C
- Intuitive microprocessor-based controller with configurable display for field programming
- Auto-calibration and auto-verification
- Auto Blow-back feature for use in extremely harsh environments
- Optional platinum-catalyst combustibles sensor measures CO & H2 for detecting incomplete combustion

- Microprocessor-based
- Fail-safe diagnostics
- RS232 digital and 4mA to 20mA analog outputs
- Easily serviced
- Weatherproof and explosion-proof packages available

The microprocessor-based electronics of the Series 300 can display the usual percent excess oxygen and trace combustibles in flue gas. In addition, special parameters such as air factor, combustivity index, excess fuel and equivalent combustibles can also be displayed with the touch of a button on the membrane keypad. At the flip of a switch, the Series 300 electronics makes a specific fuel—such as natural gas, oil or coal—the default fuel. Thereafter, all calculations are based on the selected fuel.
The Series 300 analyzer is available in horizontal or vertical mounting configurations in either weatherproof or explosionproof packages. The Series 300 digital display is available in rack, bench, panel, weatherproof and explosionproof packages. Built-in diagnostic features, such as sensor open circuit, analyzer plugging and sensor aging, are included as part of the software package. Linear output in the form of voltage or current and one alarm relay are available for both the oxygen and combustibles sensors.- Measures excess oxygen and combustibles in flue gas
- Ultrastable furnace provides best accuracy
- Temperatures from 392 to 3,092 °F (200 to 1,700 °C)
- Proprietary coatings extend oxygen sensor life
- Plug-resistant, filter-free probe
- Heater block prevents condensation and corrosion
- Diffusion/convection loop limits particulate entry

This analyzer features extremely stable sensor operation. Calibration checks or adjustments are seldom required, thus ensuring many months of trouble-free operation. When calibration checks are required, a one-point calibration is sufficient for the entire measurement range from ppm to percent oxygen
- Measures oxygen from 0.1 ppm to 100 percent in gases
- Accuracy increases at low oxygen concentrations
- Fast response: 90 percent of step change in 1 second