Optica - Chilled Mirror Hygrometer
OPTICA
The Optica Hygrometer offers precision dew point measurement. Precisely controlled by GE's chilled mirror sensing technology - providing NIST traceable humidity,temperature and pressure measurement anywhere via the worldwide intranet.

The Optica Hygrometer measures dew point temperature by regulating the temperature of a polished metal mirror by the use of optical feedback such that a constant mass of dew or frost is maintained. The temperature of the mirror is measured with a precise PRTD and is by definition equal to the dew or frost point.

Features
  • Simultaneously measure and display dew point, temperature, and pressure
  • Display any humidity parameter
  • Ethernet ready, so you can access GE Optica hygrometers via the Internet for remote monitoring applications
  • Data logger function lets you record & upload weeks of data
  • Primary NIST Traceable Humidity Transfer Standard
  • Accuracy to +/- 0.15°C
OPTISONDE - Chilled Mirror Hygrometer
Dew 10 - Chilled Mirror Dew Point Transmitter
MR2350 RH-Plus Industrial Humidity Analyzer
MG101
The RH-Plus MR2350 is a moisture analyzer designed to operate with the GE MDR3 relative humidity probe. The unit off ers an optional input that can be used for pressure compensation, an external temperature probe, or other analog transmitter.

The standard product comes with one current output (0/4 to 20 mA), a system alarm relay, and three adjustable relays, all with single-pole doublethrow 2.5 A contacts, selectable failsafe mode, and adjustable hysteresis. One or two additional analog outputs are available. A display and fi ve push buttons form the user interface for data display, unit selection, output ranges, alarm setpoints and special functions.

The RH-Plus MR2350 is available in both wall mount and panel mount configurations.
Features
  • Optional analog input for pressure compensation or other analog transmitter (voltage or current)
  • One, two or three analog outputs (0/4 to 20 mA or 0/1 to 5 VDC)
  • Three confi gurable relay outputs plus system alarm relay.
  • Two-line LCD and fi ve push button user interface.
  • RS485 serial output
  • Full complement of pre-programmed moisture measurement units
MR2350 - RH Plus Industrial Humidity Analyzer
MMR30 - DewPro Transmitter
MMR31 - DewPro Transmitter
MMR101 - DewPro Transmitter
MDR3 - Industrial Humidity & Temperature Probe
Trace Moisture Transmitters and Analyzers
MMY30 DewPro Transmitter
MMY31 DewPro Transmitter
MMY245 DewPro Portable Moisture Analyzer
MMY2650 Moisture Analyzer
DY5 Process Moisture Probe
55C150 Connection Cable for DY55 Moisture Probe, MMY150
TFC Threaded Flow Cell
VFC VCR Flow Cell
IS Intrinsic Safety Barrier
GEITAGS