- AC Input:
100/120/220/240 VAC +10%, -13%.
47-63 Hz.
Tolerance for 230 VAC operation is +15%, -10%.
Derate output current 10% for 50 Hz operation.
See chassis A.C. connection table for jumper and line fusing
requirements.
- DC Output:
See Voltage/Current Rating
Charts.
Adjustment range ±5% minimum.
Voltage nonadjustable on "3 terminal regulator" outputs of
models IHAD12 and IHAD15.
- Line Regulation:
±.05% for a 10%
line change.
Exceptions:
±.01% for F case models
±1% for IHAD12 and IHAD15
±0.5% for all other outputs using 3 terminal regulators.
Load Regulation:
±.05% for a 50%
load change.
Exceptions:
±.02% for F case models
±1% for IHAD12 and IHAD15
±0.5% for all other outputs using "3 terminal regulators.
Output Ripple:
5 Volt to 28 Volt units: 5mV
pk-pk maximum
48 Volt to 155 Volt units: .02% pk-pk maximum
200 Volt & 250 Volt units: .05% pk-pk maximum
3 Terminal Regulator units: 0.2% pk-pk maximum
Transient
Response:
Less than 50”sec for a 50% load
change.
Short Circuit and Overload
Protection:
Automatic current limit/foldback.
Overvoltage Protection:
Provided on 5V outputs where
indicated set at 6.3V ±0.4V.
Other outputs use optional overvoltage protectors IOVP12 and
IOVP24.
Remote Sensing:
See Voltage/Current Rating
Charts. Provided on outputs where indicated.
|
- Stability:
±0.3% for 24 hours after 1 hr.
warm-up.
- Temperature Ratings;
Operating:
0șC to 50șC full rated,
derated linearly to 40% at 70șC.
(Recommended forced air at 200W, 50 CFM required at 250W)
Storage:
- Temperature Coefficient:
.01%/șC typical, .03%/șC
maximum.
- Efficiency (typical)
5V
outputs:.............................45%
12V and 15V outputs.............55%
24V through 250V outputs...60%
- Master/Slave Operation:
Provided on F case models only.
For parallel operation of up to 6 units.
- Vibration:
Random vibration from 10Hz to
2KHz, 6.15grms (3 axis).
- Shock:
Operating 20G peak acceleration.
- EMI/RFI:
These linear power supplies have
inherently low conducted and radiated noise levels. For most system
applications they will meet the requirements of (FCC) 47CFR15J and
EN55022.
- Safety Agency Certifications:
UL: 1950, Third Edition
CUL: CAN/CSA C22.2 No. 950-95, IEC950
TUV Rheinland: EN 60950: 1992 + A1 + A2 + A3 + A4 + A11
CE Mark: LVD 73/23/EEC
- Leakage Current &
Dielectric Withstand
Leakage current is less than 50”A.
Field terminal to terminal spacing is 5.25 mm with 9.0 mm creepage
to other metal. Dielectric withstand voltages are 3750 VAC input to
chassis, 3750 VAC input to output and 750 VDC output to chassis. UL
tested at 4242 VDC input to output, 2121 VDC input to dead metal.
|