TRANSMITTERS 4-20 MA

4-20 mA Current Output Transmitter for Process Signal Input
4-20 mA Current Output Transmitter for Process Signal Input
Totalizer for 0-1 mA, 4-20 mAor 0-10V Signals 4-20 mA Current Transmitter Scalable for flow rate or total flow.DIN Rail mounted, digitally programmable accepts signals from flow meters and other transducers, such as watt meters, to track rate or totalized rate.With a Standard Main Board, the transmitter output can track rate (such as gallons per minute or watts) or totalized rate (such as gallons or kilowatt hours) whether the transducer output is linear or requires square root extraction (differential pressure flow transducers).With an Extended Main Board, the transmitter can also perform custom curve linearization (provided by a curvilinear spline fit with up to 180 data points),
4-20 mA Current Output Transmitter for Strain Gauge & Potentiometer Input
4-20 mA Current Output Transmitter for Strain Gauge & Potentiometer Input
Process, Strain Gauge & Potentiometer Follower Input 4-20 mA Current Transmitter Scalable for process, strain, pressure, level, flow .DIN Rail mounted, digitally programmable, provides six DC voltage ranges and four DC current ranges for use with a wide range of industrial transducers whose output requires zero and span adjustment. All ranges are factory calibrated and jumper selectable. The two most sensitive voltage ranges, 200 mV and 2V, provide a high input impedance of 1 Gohm to minimize the load on the voltage signal The strain gauges with a 20 mV output can be internally scaled to display up to 10,000 counts, while outputs of 200 mV can be scaled to 99,999 counts.
4-20 mA Thermocouple Transmitter
4-20 mA Thermocouple Transmitter
The Laureate 4-20 mA thermocouple transmitter provides a linearized, highly accurate, stable and repeatable transmitter output for thermocouple types J, K, T, E, N, R or S. The thermocouple or RTD type and temperature range, specified in °C or °F, are user-selectable. The temperature range can be as wide as the entire span of the thermocouple type, or as narrow as 150 counts, limited only by considerations of electrical noise and digital filtering time constants. Digital calibration of all thermocouple ranges is performed the factory, with calibration data stored in EEPROM on the signal conditioner board. This allows signal conditioner boards and ranges to be changed in the field with no need for recalibration.
4-20 mA Current Output RTD Temperature Transmitter
4-20 mA Current Output RTD Temperature Transmitter
The Laureate 4-20 mA RTD temperature transmitter provides a linearized, highly accurate, stable and repeatable transmitter output for 100 ohm platinum, 10 ohm copper and 120 ohm nickel RTDs. Pt 100 platinum RTDs can have a DIN alpha of 0.00385 or ANSI alpha of 0.00392. The RTD type and temperature range, specified in °C or °F, are user-selectable. The temperature range can be as wide as the entire span of the RTD type or as narrow as 150 counts (such as 15.0°), limited only by considerations of electrical noise and digital filtering time constants. Digital calibration of all RTD ranges is performed the factory, with calibration data stored in EEPROM on the signal conditioner board.
4-20 mA Current Output Transmitter & Dual Pulse Input Totalizer
4-20 mA Current Output Transmitter & Dual Pulse Input Totalizer
Dual Pulse Input Totalizer 4-20 mA Current Transmitter Rate or total in same transmitter, square root extraction. DIN Rail mounted, digitally programmable Laureate TM Series serial output, pulse input totalizer transmitters accept two independently scalable input channels from a wide range of pulse sources, such as NPN or PNP proximity switches, contact closures, digital logic, magnetic pickups down to 12 mV, or AC voltages to 250 Vac. Input pulse rates can be as high as 1 MHz.With a Standard Main Board, the transmitter output can be scaled to engineering units.
4-20 mA Current Output Transmitter & Totalizer for 0-1 mA, 4-20 mA or 0-10V
4-20 mA Current Output Transmitter & Totalizer for 0-1 mA, 4-20 mA or 0-10V
Laureate™ Modbus or Laurel ASCII Protocol Serial Output DIN Rail Transmitters DIN Rail mounted, digitally programmable.Exceptional accuracy at high update rates.Laureate TM Series serial output transmitters can be jumpered for two signal levels: RS232 or RS485. Two serial protocols are selectable in software: Modbus or Laurel's Custom ASCII. Modbus protocol operation is fully compliant with the Modbus Over Serial Line Specification V1.0 (2002) for 2-wire, half-duplex connection. This includes RTU or ASCII modes, addressing of up to 32 devices per RS485 line without a repeater, and up to 247 digital addresses. Modbus operation allows devices by different manufacturers to be connected in parallel and be addressed using the same protocol
4-20 mA Current Output Transmitter for Ratio
4-20 mA Current Output Transmitter for Ratio, Product, Sum or Difference of 2 Rates or Totals
Sum, Difference, Ratio, Product for Rate or Total with 2 Input Channels4-20 mA Current Transmitter DIN Rail mounted, digitally programmable. pulse input transmitters accept two independently scalable input channels A & B from a wide range of pulse sources, such as NPN or PNP proximity switches, contact closures, digital logic, magnetic pickups down to 12 mV, or AC voltages to 250 Vac. Input frequencies can range from 0.005 Hz to 1 MHz. With the Standard main board, the transmitter output can be programmed to track rate or total for both channels.
4-20 mA Current Output Transmitter for AC Phase Angle & Power Factor
4-20 mA Current Output Transmitter for AC Phase Angle & Power Factor
AC Phase Angle Input 4-20 mA Current Transmitter For angular phase offset in degrees of AC waveforms.DIN Rail mounted, digitally programmable The 4-20 mA output of Laureate AC phase angle transmitter indicates the lead or lag in degrees from 0º to 360º between two periodic signals having the same period. The signals are applied to the Channel A and B inputs of the Laureate dual-channel pulse input signal conditioner board. Phase angle measurement is commonly used with AC power from 50 Hz to 400 Hz. Phase angle needs to be set to zero to synchronize AC generators. It also applies to the triggering of SCRs and Triacs for power control.
4-20 mA Current Output Transmitter for Time of Single or Accumulated Events
4-20 mA Current Output Transmitter for Time of Single or Accumulated Events
Stopwatch Input 4-20 mA Current Transmitter Resolution to 0.2 µs. Duration to 999,999 hrs. DIN Rail mounted, digitally programmable The Laureate TM Series serial output stopwatch transmitter performs all of the functions of the Laureate panel mount stopwatch, except for the display. The data retrieved via serial commands can be the time of individual events (Item #1) which produce start and stop pulses, or accumulated time of multiple events (Item #2). The highest resolution is 0.2 µs, making the transmitter ideal for fast events. The longest timing interval is 999,999 hrs. There are two primary timing modes:A-A Stopwatch Mode. Time is measured between a start pulse and a stop pulse, both on Channel A, from either the positive or negative edges. A-B Stopwatch Mode. Time is measured between a start pulse on Channel A and stop pulse on Channel B (positive or negative edge).
4-20 mA Current Output Transmitter for Time Interval of Periodic Events
4-20 mA Current Output Transmitter for Time Interval of Periodic Events
Time Interval of Periodic Events 4-20 mA Current Transmitter From from 1 µs to 199.999 s. Resolution to 0.2 µs. DIN Rail mounted, digitally programmable. The Laureate 4-20 mA transmitter for periodic time events can transmit pulse width or time delay between individual pulses to a resolution of 0.2 µs. It can also display average pulse width or average time delay between multiple pulses. Selectable full-scale ranges go from 0.099999 sec with 0.2 µs resolution (after averaging) to 199.999 sec with 1 ms resolution. Time interval is measured between inputs on channels A and B. Timing starts when a pulse is applied to Channel A (selectable positive or negative edge), and ends when a pulse is applied to Channel B (selectable positive or negative edge). In case of a single pulsed signal, the A and B inputs can be tied together.
4-20 mA Current Output Transmitter for Position or Rate from Quadrature Encoders
4-20 mA Current Output Transmitter for Position or Rate from Quadrature Encoders
Quadrature Position or Rate 4-20 mA Current Transmitter Transmits accurate position or rate from quadrature encoders. DIN Rail mounted, digitally programmable. Laureate 4-20 mA quadrature transmitters accept the A & B signals from shaft encoders to provide a highly accurate reading of position, length, angle, or rate. The A & B quadrature signals are 90º out of phase, and their phase relationship determines whether up counts (+) or down counts (-) are produced. One, two or four transitions may be counted at a maximum combined rate of 250 kHz and be scaled internally from -999,999 to +999,999. counts. The input circuitry which may be jumpered for either single-ended input signals or for balanced line driver signals. Power fail or zero index capabilities are alternate meter setup choices.
4-20 mA Current Output Transmitter for Duty Cycle Input
4-20 mA Current Output Transmitter for Duty Cycle Input
Duty Cycle Input 4-20 mA Current Transmitter Transmits ON or OFF period in percent. DIN Rail mounted, digitally programmable. The 4-20 mA output of the Laureate duty cycle transmitter tracks ON or OFF period as a percentage from 0% to 100% of total period of repetitive pulse trains. In the illustration, duty cycle is 100 x t/P. The transmitter determines duty cycle by averaging an integral number of periods over a gate time, which is selectable from 10 ms to 199.99 s. The same signal is applied to Channels A and B. The meter divides the average pulse width by the period between pulses and expresses this ratio in percent. A resolution of 1%, 0.1% or 0.01% is selectable. By selecting leading or falling pulse edges, the ON or OFF duty cycle can be transmitted.Duty cycle measurement is used to monitor modulated proportional control systems and pulse-modulated systems.
LTS6 Serial-to-Analog DIN Rail Transmitter
LTS6 Serial-to-Analog DIN Rail Transmitter
Converts serial data to a scaled analog signal. The Laureate LTS6 serial input to analog output transmitter accepts RS-232 or RS-485 serial data with the Modbus or Laurel ASCII protocol, and converts it to an isolated, scalable 4-20 mA, 0-20 mA or 0-10V analog output signal. The unit fits on a 35 mm DIN rail and is only 22.5 mm (0.89") thick. It is normally powered by AC (85-264 Vac), but can optionally be powered by low voltage AC or DC. All electrical connections are via detachable screw-clamp plugs. Standard features of the LTS6 include Analog transmitter output, 16-bit, scalable and isolated. Serial communications, isolated. User selectable RS232 or RS485, half or full duplex. as well as Dual solid state relays for control or alarm, isolated. Rated 120 mA at 130 Vac or 170 Vdc. And Universal AC power supply for 85-264 Vac.