LaureateT Time Interval
& Stopwatch Meters
For periodic time measurement & one-time
events


Common
Features
- Inputs from NPN or PNP proximity
switches, contact closures, digital logic, magnetic pickups down to 12 mV, or AC inputs up
to 250 Vac.
- Trigger on positive or negative pulse
edges.
- 6-digit red or green LED display.
- Isolated 5, 10 or 24 Vdc excitation
output to power sensors.
- Green or red LED display.
- NEMA 4X front panel, 1/8 DIN case.
- Choice of options:
Dual 10A relays
4-20 mA & 0-10
V analog output
RS-232/485 data I/O
Parallel BCD output.
- Certified to UL 3101-1, CAN/CSA-C22.2,
EN 61010-1 (CE Mark).
|
Time Interval
Mode
- For periodic events from 1 µs to 199.99
s.
- Display resolution to 0.2 µs.
- Uses Standard counter main board and FR
signal conditioner.
Stopwatch
Mode
- Times single events with start and stop
pulses from 1 ms to 99 hrs.
- Selectable display of single event time
or accumulated time of all events up to 999,999 hrs.
- Selectable display in HH.MM.SS clock
format or H, M or S up to 6 digits with decimal point.
- Uses Extended counter main board and FR
signal conditioner.
|

Description
The Laureate time interval and stopwatch
timers use the FR dual-channel signal conditioner and either the Standard counter main
board (time interval) or Extended counter main board (stopwatch).
A-B Time Interval Mode
The Laureate time
interval meter displays pulse width or time delay between pulses for single pulses or the
average for multiple pulses. Time interval is measured between inputs on channels A and B.
Timing starts when a pulse is applied to Channel A (selectable positive or negative edge) and ends when a pulse is
applied to Channel B (selectable positive or negative edge). In case of a single pulsed
signal, the A and B inputs can be tied together. A positive or negative slope may be
selected to start timing, and the opposite slope must be selected to stop timing.
Timing is achieved by counting 5.5 MHz clock
pulses. Multiple integral time intervals are averaged over a gate time which is selectable
from 10 ms to 199.99 s and also controls the display update time. The default display is
in µs. Display resolution down to 0.2 µs can be achieved by applying a multiplier of 10,
moving the decimal point by one position, and averaging many time intervals. Resolutions
up to 1 s or greater are also programmable.
Stopwatch Mode
The Laureate stopwatch
meter is designed to time single events, such as sporting events or processes, which
produce start and stop pulses. It can also time the width of a single pulse. The display
is updated continuously during timing.
Display
The event time (Item #1) may
be displayed in HH.MM.SS clock format with 1 s resolution or in H, M or S seconds with
six-digit resolution . The longest timing interval is 99 hours. The highest resolution is
1 ms.
The stopwatch display is updated during timing
at a rate controlled by gate time, up to 25/s. It is reset to zero when the next start
pulse occurs. Accumulated time from multiple events (Item #2) is also tracked and may be
displayed up to 999,999 hours.
Universal Signal
Conditioner
The dual-channel signal
conditioner used for pulse detection accepts inputs from proximity switches with PNP or
NPN output, TTL or CMOS logic, magnetic pickups, contact closures, and other signals from
12 mV to 250 Vac. Nine hysteresis and input levels are
jumper selectable for reliable triggering. A 1600 Hz low-pass roll-off filter for noise
reduction and contact debounce times of 3 ms or 50 ms are also selectable.
A built-in isolated 5, 10, or 24 Vdc
excitation supply can power proximity switches and other sensors, and eliminate the need
for an external power supply.
Other Features and
Options
Plug-in isolated analog
output, dual setpoint controller and RS232/485 communications or BCD output boards can
upgrade the Laureate from a stand-alone monitor to system interface and control. Laureate meters
and counters meet NEMA 4X (IP-65) standards from the front for high pressure washdown when
panel mounted. All power and signal connections are via plug-in screw-clamp connectors.
|

Specifications
| Display |
Readout
Color
Range
Indicators |
6 digits, 7-segment, 14.2 mm (.56")
Red or green LED
-999999 to +999999
Four LED lamps |
| Inputs |
Types
Grounding
Channel A Frequency
Channel B Frequency
Selectable Hysteresis
Rolloff Filter
Debounce Time |
AC,
pulses from NPN, PNP transistors, contact closures, magnetic pickups
Common ground for channels A & B
0.005 Hz to 1 MHz
0.005 Hz to 250 kHz
(-12 mV to +12 mV), (+30 mV to +60 mV),
(-30 mV to -20 mV), (-150 mV to +150 mV),
(+350 mV to +600 mV), (-600 mV to -350 mV),
(-1.15 V to +1.15 V), (+1.25 V to +2.1 V),
(-2.1 V to -1.25 V)
Selectable, none or 1600 Hz
Selectable 0, 3, 50 ms |
| Time
Interval Mode |
Timing Start
Timing Stop
Periodic Timing Interval
Gate Time
Timeout
|
Channel
A pulse, + or - edges
Channel B pulse, + or - edges
Gate time + 30 ms + 0-2 time intervals
Selectable 10 ms to 199.99 s
Selectable 10 ms to 199.99 s
Same as periodic timing interval |
| Stopwatch
Mode |
Timing Start
Timing Stop
Timing interval
Timing Resolution
Selectable Decimal Time
Selectable Clock Time
Output & Display Update |
Channel
A start pulse, + or - edge
Channel A stop pulse, same edge polarity as start pulse,
or Channel B pulse, opposite edge polarity as start pulse.
1 µs to 99 hrs
1 µs
999999 H, M or S, any decimal point
HH.MM.SS
Gate time |
| Accuracy |
Time Base
Span Tempco
Long-term Drift |
Crystal
calibrated to ±2 ppm
±1 ppm/°C (typ)
±5 ppm/year |
| Power |
Voltage,
std.
Voltage, opt.
Frequency
Power isolation
|
85-264
Vac and 90-370 Vdc
8-28 Vac and 9-37 Vdc
DC or 49-440 Hz
Safety-rated to 250 Vac, meter ground to earth ground,
DC to 60 Hz, 4.2 kVp per High Voltage Test
|
| Excitation Output |
5
Vdc
10 Vdc
24 Vdc
Output isolation
|
5
Vdc ±5%, 100 mA max
10 Vdc ±5%, 120 mA max
24 Vdc ±5%, 50 mA max
50 Vdc to meter ground
|
| Environmental |
Operating
Temperature
Storage Temperature
Relative Humidity
Protection
|
0°C
to 55°C
-40°C to 85°C
95% at 40°C, non-condensing
NEMA-4X (IP-65) when panel mounted
|
| Electrical Connections |
 |
|

|
Applications |
Time Interval Mode for Time Delay |
 |
For periodic pulses applied to A and B channels, time
delays can be measured down to 0.2 µs resolution from the rising or falling edge of A to
the rising or falling edge of B (selectable).
|
Time Interval Mode for Pulse Width |
 |
The width of periodic pulses (t1 or t2) can be measured by
tying the A and B channels together. As for time delay, readings are averaged over a
user-selectable gate time.
|
Stopwatch Mode |
 |
The stopwatch mode is used to time single events between
start and stop pulses on the same channel. Duration of a single waveshape can be measured
by tying the A and B channels together.
|
Timing Process Dynamics |
 |
The start and stop pulses used for timing can be generated
by the dual relay board in a Laureate analog panel meter or digital counter. For instance,
the start and stop pulse edges can be created as temperature passes two alarm setpoints,
or temperature cycles in a hysteresis control mode.
|
Replacing an Oscilloscope with a Laureate |
 |
An oscilloscope can be used for viewing pulses. However, a
Laureate time interval meter is the instrument of choice if high timing accuracy or
control outputs are required.
|
Instrumenting a Pulsed Laser System |
 |
Some of the many possibilities in instrumenting a pulsed
laser system with Laureate dual-channel counters.
|