Partlow MIC 1460

Partlow MIC 1460
Quick Specification:
1/4 DIN, microcontroller based, PID controller and setpoint programmer with dual display and Adaptive Tuning. Includes Loop Break Alarm for heater break detection without additional hardware.
Read more for Mechanical Limits
  • Standard Features
  • Optional Features
  • Key Specifications
  • Agency Approvals
  • Manual
  • Dual 4 digit red displays for process value and setpoint
  • 8 Character alphanumeric display for profile name and prompts
  • Profile and segment number displays
  • 12 Status LEDs
  • 8 Programs, 16 segments with program joining
  • Full PID with Pre-Tune and Adaptive Auto-Tuning on dwells
  • Assured soak
  • Delayed start
  • End of program relay output
  • Universal sensor input: thermocouple, RTD, mA, mV, or V
  • Relay or SSRD first output (mA optional)
  • Configurable from an IBM compatible computer
  • 90 to 264V AC powered
  • 4 Event relay outputs
  • Remote program select, run, hold, and abort
  • Dual outputs for heat-cool applications
  • Additional relay, SSRD, or mA outputs
  • Up to two alarms
  • On-line Program Editor
  • RS-485 Communications
  • 24V Transmitter power supply
  • 24V AC/DC powered operation
  • +/- 0.25% Accuracy
  • 4 Scans per second
  • 2A SPDT Relay outputs
  • IP65/NEMA 4 Panel mount sealing
  • 3.94" Panel depth
  • 3 Year warranty
  • UL Recognized
  • cUL Certified for Canada
  • CE Compliance
 
 