Cold junction compensation automatically corrects for temperature variations at the thermocouple reference junction at the meter. Open sensor indication is standard and may be set up to indicate either upscale or downscale. RTD excitation is provided by the meter. RTD connections can be of the 2-, 3- or 4-wire type. For 3- and 4-wire connections, the meter automatically compensates for lead resistance of the sensor.
All ranges for all temperature sensor types are digitally calibrated at the factory. This eliminates the need for field calibration or drift caused by potentiometers found in non-microcomputer based meters.All Laureate digital panel meters allow exceptionally fast read rates. Concurrent Slope (Pat 5,262,780) is a method of analog-to-digital conversion that allows up to 60 conversions per second while integrating the input over a full power cycle. Fast read rates provide true readings and fast response for control applications. Display of peak value is standard.
Plug-in isolated analog output, dual-setpoint controller and RS-232/485 communications or BCD output boards can upgrade the Laureate from stand-alone monitor to system interface and control. The Laureate temperature meter can serve as a highly accurate, isolated, 4-20 mA transmitter.Laureate panel meters are available with a red or green LED display. Blanking of leading, non-significant zeros simplifies reading. The 1/8 DIN case is water tight to NEMA 4X (IP-65) from the front when mounted in the panel.
| Thermocouple Input | |||
| TC Type | Range | Conformity Error | |
| J | -210°C to +760°C -347°F to +1400°F |
0.09°C 0.16°F |
|
| K | -244°C to +1372°C -408°F to +2501°F |
0.1°C 0.17°F |
|
| T | 0°C to +400°C -257°C to 0°C +32°F to 752°F -430°F to +32°F |
0.03°C 0.2°C 0.05°F 0.36°F |
|
| E | -240°C to +1000°C -400°F to +1830°F |
0.18°C 0.32°F |
|
| N | -245°C to +1300°C -410°F to +2370°F |
0.10°C 0.17°F |
|
| R | -45°C to +1768°C -49°F to +3214°F |
0.17°C 0.31°F |
|
| S | -46°C to +1768°C -51°F to +3213°F |
0.12°C 0.22°F |
|
| Applicable to all TC types | |||
| Calibration | NIST Monograph 125 (IPTS-68) | ||
| Input resistance | 1 Gohm | ||
| Input current | 100 pA | ||
| Max lead resistance | 1 Gohm max for rated accuracy | ||
| Span tempco | ±0.003% of reading/ºC | ||
| Reference junction tempco | ±0.02 deg/deg | ||
| Span tempco | ±0.003% of reading/ºC | ||
| Overvoltage protection | 125 Vac | ||
| NMR at 50/60 Hz | 80 dB plus selectable digital filter from 80 ms to 9.6 s time constant |
||
| CMR, DC-60 Hz | 120 dB with 500 W imbalance | ||
| CMV, DC-60 Hz | 250 Vac from power and earth grounds | ||
| Open sensor indication | Flashes full-scale | ||
| RTD Alpha | Range | Conformity Error | |
| DIN .00385 |
-202°C to +850°C -331°F to +1562°F |
0.03°C 0.05°F |
|
| ANSI .003925 |
-202°C to +631°C -331°F to +1168°F |
0.04°C 0.07°F |
|
| Applicable to all RTD types | |||
| Calibration, DIN | IEC 751 (IPTS-68) | ||
| Calibration ANSI | NIST Monograph 126 | ||
| Configuration | 2, 3 or 4-wire connection | ||
| Excitation current | 0.2 mA | ||
| Span tempco | ±0.003% of reading/ºC | ||
| Zero tempco | ±0.03 deg/deg | ||
| Sensor lead resistance | 2-wire, 10 mdeg/W/deg up to 10 W | ||
| tempco per conductor | 3 & 4-wire, 10 mdeg/W/deg up to 100 W | ||
| Overvoltage protection | 125 Vac | ||
| Open sensor indication | Flashes full-scale | ||
| Display | A-to-D Conversion | Power | Environmental | ||||
| Readout |
5 digits, 7-segment, 14.2 mm (.56") |
Technique | Concurrent Slope™ (Pat 5,262,780) | Voltage, std. | 85-264 Vac and 90-370 Vdc | Operating Temperature | 0°C to 55°C |
| Color | Red or green LED | A-to-D Rate | 60/s at 60 Hz, 50/s at 50 Hz | Voltage, opt. |
8-28 Vac and 9-37 Vdc | Storage Temperature | -40°C to 85°C |
| Indicators | Minus sign, 2 red LED lamps | Output Update | 56/s at 60 Hz, 47/s at 50 Hz | Frequency | DC or 49-440 Hz | Relative Humidity Protection |
95% at 40°C, non-condensing NEMA-4X (IP-65) when panel mounted |
| -- | -- | Display Update | 3.5/s at 60 Hz, 3/s at 50 Hz | Power isolation | Safety-rated to 250 Vac, meter ground to earth ground, DC to 60 Hz, 4.2 kVp per High Voltage Test |
-- | -- |
|
The Laureate temperature meter allows 2-, 3- and 4-wire RTD hookup to the J5 connector. The meter applies an excitation current of 0.2 mA, which it monitors to make ratiometric corrections for excitation supply variations. |
|
In 2-wire hookup, the meter senses the voltage drop across the 100 ohm RTD and both lead wires. The effect of the lead wires can be measured and subtracted by shorting out the RTD during meter setup. |
|
In 3- and 4-wire hookup, the meter senses the voltage drop across the 100 ohm RTD and both lead wires as well as the voltage drop across the RTD and one lead wire. This allows it to determine the effect of one lead wire and mathematically subtract the effect of both lead wires. |



Multiple setpoint operating modes are individually selectable for each relay, as explained in the dual-setpoint controller section. Relay duty cycles and chatter can be minimized with programmable hysteresis and time delays. High duty cycles and extremely fast response times are possible with the solid state relay, which has a typical response time of only 17 ms.